0000789MEGASequence Data Explorerpublic2018-05-31 07:522018-06-26 07:58
guest 
gstecher 
normalminorhave not tried
resolvedfixed 
PCWindows7
MEGA 11 (Graphical Interface version) 
 
Christina
Knyaz
tuf14192@temple.edu
tuf14192@temple.edu
0000789: Error When Analyzing MAS file
This is a bug that Louise reported. When opening the mas file attached below, the file opens fine in the alignment explorer, but fails to open in the Sequence Explorer when clicking on 'Analyze'. There is some error reading the file and it gets stuck in the BlockRead(f, c, 1) function call in the RetriveMegaAlignmentSession function in the ProcessInputdata unit around line 2435. It throws an EInOutError with message Read past end of file.
No tags attached.
? Hemo4.mas (2,358) 2018-05-31 07:52
https://megasoftware.net/mantis_bt/
Issue History
2018-05-31 07:52guestNew Issue
2018-05-31 07:52guestFile Added: Hemo4.mas
2018-05-31 11:22gstecherNote Deleted: 0000744
2018-06-26 07:58gstecherNote Added: 0004045
2018-06-26 07:58gstecherStatusnew => resolved
2018-06-26 07:58gstecherResolutionopen => fixed
2018-06-26 07:58gstecherAssigned To => gstecher

Notes
(0004045)
gstecher   
2018-06-26 07:58   
fixed by Christina