MantisBT

View Issue Details Jump to Notes ] Issue History ] Print ]
IDProjectCategoryView StatusDate SubmittedLast Update
0002662MEGAAlignment Explorerpublic2021-03-23 06:592021-03-25 10:07
Reporterguest 
Assigned Togstecher 
PrioritynormalSeverityminorReproducibilityhave not tried
StatusresolvedResolutionfixed 
PlatformPCOSWindows 
Product Version 
Target VersionFixed in Version 
Summary0002662: Access Violation Error Loading .fas file
DescriptionHi Everyone-

I have downloaded and installed MEGA X on two computers. One has 16 Gb of RAM, while the other computer has 32 Gb of RAM.

I began my MEGA X session by attempting an alignment. In each instance, I received the following error message in the Alignment Explorer:

Application: Error: failed to load fasta file; Access Violation

For both of the computers, I also have MEGA 7 installed. When I load the same .fas file with MEGA 7, the program works properly.

MEGA X has some features I would like to incorporate into my analysis, so I would like to solve this loading issue.

Any ideas on how to resolve the loading issue with MEGA X.

Thanks for any help.

Phil
TagsNo tags attached.
Attach Tags (Separate by ",")
First NamePhillip
Last NameMcClean
Emailphillip.mcclean@ndsu.edu
Confirm Emailphillip.mcclean@ndsu.edu
Attached Files? file icon F35H-all-sequences.fas (93,499 bytes) 2021-03-23 06:59

- Relationships

-  Notes
(0002079)
user614
1969-12-31 17:33

Hello Andrew,

We received your bug report regarding the failed installation of the MEGA 5 full release on your Mac computer. In order to diagnose what went wrong with the installation it would help us greatly if you could send us the installation log that MEGA creates during install. This file will be located at ‘your home directory/MEGA/MEGAInstallLog.txt’. Also, because the installation failed but you were able to install the beta version previously, there should be another installation log file (from the beta install) located at ‘your home directory/MEGAInstallLog.txt’. If you could send me both of these files it would really help is in figuring out why the installation failed and fixing the problem.

Best regards,

Glen Stecher
(0002610)
user614
1969-12-31 17:33

This problem only occurs with the old style of installer. Fixed when we switched to Wineskin.
(0004564)
gstecher (administrator)
2021-03-25 10:07

fixed in 10.2.5

Hi Phillip,

I am writing in response to the bug report you recently submitted regarding the MEGA software. The file you uploaded is malformed. To see this, open the file in a text editor and at the end of line 248 there is AMVTPRLSLDVYRCN.menziesii-FH which looks like the name of the next sequence in the file. Anyway, thanks for the feedback. We will update MEGA to show an informative message in this case in the future.

Best regards,
Glen Stecher
Institute for Genomics and Evolutionary Medicine
igem.temple.edu

- Issue History
Date Modified Username Field Change
1969-12-31 17:33 user19 Status new => assigned
1969-12-31 17:33 user19 Assigned To => user614
1969-12-31 17:33 user614 Note Added: 0002079
1969-12-31 17:33 user614 Note Added: 0002610
1969-12-31 17:33 user614 Status assigned => closed
1969-12-31 17:33 user614 Resolution open => fixed
2021-03-23 06:59 guest New Issue
2021-03-23 06:59 guest File Added: F35H-all-sequences.fas
2021-03-25 10:07 gstecher Note Added: 0004564
2021-03-25 10:07 gstecher Status new => resolved
2021-03-25 10:07 gstecher Resolution open => fixed
2021-03-25 10:07 gstecher Assigned To => gstecher


Copyright © 2000 - 2024 MantisBT Team